Do You Have A Construction Project We Can Help With?
ELECTRICAL ITEMS
Diligent is an Authorized distributor of World class cables manufacturer, TOPCABLE SPAIN Specially for Low smoke Halogen free cables and Rubber Cables.
TYPE | Application | Design | Conductor | Insulation | Outer sheath | International norm: | Characteristics |
---|---|---|---|---|---|---|---|
LSHZ TOXFREE RZ1-K AS | TOXFREE ZH RZ1-K AS is a LSZH safety cable. In the event of fire, it does not emit toxic gases,nor does it give off corrosive gases, avoiding any possible damage to people or electronic equipment.
For these reasons it is highly recommended for use in public places such as: hospitals, schools, museums, airports, bus terminals, shopping malls, offices, laboratories, etc. |
This type of cable is designed, manufactured and tested according to IEC 60502-1. | Electrolytic annealed copper conductor, class 5 according to IEC 60228. | Cross-linked polyethylene insulation, type XLPE according IEC 60502-1 and type DIX-3 according to HD 603. |
LSZH polyolephine outer sheath. Green color, non-toxic and fire retardant. | IEC 60332-1 / IEC 60332-3 / IEC 60754-1 / IEC 60754-2 / IEC 61034 | Nominal voltage: 0,6/1 (1,2) kV Maximum operating temperature: 90 ºC Minimum operating temperature: -40 °C (static, with protection) Minimum installation and handling temperature: 0 °C Maximum short-circuit temperature: 250 °C (maximum 5 s.) Minimum bending radius (static): 5 x cable Ø |
XTREM HO7RNF | XTREM H07RN-F rubber cables are designed to supply power to low voltage appliances including electric motors and submersible pumps in deep water installations as well as many other types of electrical equipment.
Thanks to its extraordinary flexibility and mechanical strength, the Xtrem H07RN-F cable is ideal for power transmission in both fixed installation or mobile service. The nominal voltage up to 1000 V thanks to the high dielectric properties of the insulation material (according to HD 516). |
This type of cable is designed, manufactured and tested in accordance with EN 50525-2-21 and IEC 60245 | Electrolytic annealed copper conductor, class 5 according to IEC 60228. | Thermosetting rubber insulation, type EI7 according to EN 50363-1. | Thermosetting rubber outer sheath, black, type EM2 according to EN 50363-2-1. | IEC 60332-1 | Nominal voltage: 450/ 750 V Temperatures: Maximum operating: 90 ºC Min. operating: -40 °C (static, with protection) Min. installation and handling: -25 °C (on cable surface) Maximum short-circuit temperature: 250 °C. (maximum 5 s.) Minimum bending radius static: 3 x cable Ø (Ø cable <12 mm) 4 x cable Ø (Ø cable ≥12 mm |
Trusted Partners
Building Inspiring Spaces
Only takes a few seconds!